MVME51005E-0161輸出卡件
?瀏覽樹窗格中沒有狀態(tài)刷新。?數(shù)據(jù)記錄器無狀態(tài)刷新。?清除所有上載的數(shù)據(jù)記錄器。所有未保存在驅(qū)動器中的設(shè)置均設(shè)置為默認(rèn)值。?打開的參數(shù)文件已關(guān)閉。請注意,可能會顯示保存未更改更改的請求。?瀏覽樹窗格被清除。?將清除項目集。請注意,所有鎖定的項目都已解鎖,不會有任何項目在線。但是,不會刪除用戶項集中的模板。請注意,斷開連接不會關(guān)閉打開的備份或加載包。OPC服務(wù)器7-12 DriveWindow 2注意,某些DriveWindow操作需要重新啟動驅(qū)動器。重新啟動DriveWindow啟動的驅(qū)動器會導(dǎo)致OPC服務(wù)器的內(nèi)部斷開和重新連接。斷開連接的副作用仍然有效,但重新連接會將驅(qū)動器帶回瀏覽樹窗格。然而,它們的順序和可能的節(jié)點(diǎn)地址可能已經(jīng)改變。此外,所有驅(qū)動器子分支都將折疊。OPC服務(wù)器DriveWindow 2 7-13 5.1.1自動斷開OPC服務(wù)器當(dāng)您:?打開圖形文件,使DriveWindow脫機(jī)時,OPC服務(wù)器將自動斷開。?恢復(fù)未連接到當(dāng)前連接的OPC服務(wù)器的工作區(qū)。?關(guān)閉DriveWindow。?注銷或關(guān)閉Windows操作系統(tǒng)。OPC服務(wù)器7-14 DriveWindow 2自DriveWindow版本2.11以來,您必須確認(rèn)在前兩種情況下自動斷開連接,例如:另請參閱:什么是OPC服務(wù)器連接到OPC服務(wù)器6。使用DriveDA DriveDA是另一種設(shè)計用于處理ACS880系列驅(qū)動器的OPC服務(wù)器。不過,DriveWindow中不包含此功能。您需要安裝包含DriveWare的產(chǎn)品(如Drivecomposer pro),然后才能將其與DriveWindow一起使用。除了能夠本機(jī)連接到ACS880系列驅(qū)動器之外,DriveDA還可以連接到另一個OPC服務(wù)器。客戶端程序?qū)⑦@種OPC服務(wù)器的所有設(shè)備視為DriveDA的設(shè)備。此功能允許您在DriveWindow中混合使用ACS800和ACS880系列驅(qū)動器。但是,DriveWindow僅對ACS880系列驅(qū)動器提供基本支持。有幾個功能缺失或不工作。OPC服務(wù)器DriveWindow 2 7-15如果安裝了DriveDA,則在選擇要連接的OPC服務(wù)器時,您會在“選擇OPC服務(wù)器”對話框中看到它。如果您想連接到DriveDA,請選擇ABB。DriveDA而不是ABB.SMP。如果您只有ACS880系列驅(qū)動器,而您的電腦中沒有DDCS通信硬件,則每次連接到DriveDA時,您可能會對有關(guān)它的消息感到厭倦。有兩種方法可以消除此消息。如果您偶爾需要連接到ACS800系列驅(qū)動器,建議您在dwc_def文件中添加或編輯[OPC]部分。ini:[OPC]Remote=1文件位于:?Documents and Settings\All Users\Application Data\DriveWare(WinXP)或?Program Data\DriveWare
? No status refresh in the browse tree pane. ? No status refresh of dataloggers. ? All uploaded dataloggers are cleared. All those settings, which are not preserved in a drive, are set to their default values. ? Open parameter file is closed. Note that a request for saving unchanged changes may be shown. ? The browse tree pane is cleared. ? The item sets are cleared. Note that all locked items are unlocked and there will be no item on-line. However, templates in user item sets are not deleted. Note that disconnecting does not close an open backup or loading package. OPC Server 7-12 DriveWindow 2 Note that some DriveWindow operations require restarting of a drive. Restarting a drive initiated by DriveWindow does an internal disconnecting and reconnecting of the OPC Server. The side effects of disconnecting are still valid, but re-connecting brings back the drives into the browse tree pane. Their order and possibly node addresses may have changed, however. Also, all drive sub-branches will be collapsed. OPC Server DriveWindow 2 7-13 5.1.1 Automatic disconnecting of the OPC Server The OPC Server is automatically disconnected when you: ? Open a graph file, which puts DriveWindow off-line. ? Restore a workspace, which was not connected to the currently connected OPC Server. ? Close DriveWindow. ? Log off or shut down Windows operating system. OPC Server 7-14 DriveWindow 2 Since DriveWindow version 2.11 you have to confirm the automatic disconnection in the two first cases, e.g.: See Also: What is OPC Server Connecting to OPC Server 6. Using DriveDA DriveDA is another OPC Server designed to handle ACS880 family of drives. It is not included in DriveWindow, however. You need to install a DriveWare product (such as Drive composer pro) that contains it before you can use it with DriveWindow. In addition to be able to connect natively to ACS880 family of drives, DriveDA can connect to another OPC Server. All devices of such an OPC Server are seen by the client program as devices of DriveDA. This feature allows you to operate with a mixture of ACS800 and ACS880 families of drives in DriveWindow. However, DriveWindow has only a basic support for ACS880 family of drives. There are several features missing or not working. OPC Server DriveWindow 2 7-15 If DriveDA is installed, you see it listed in the Select OPC Server dialog box when selecting the OPC Server to connect to. If you want to connect to DriveDA, select ABB.DriveDA instead of ABB.SMP. If you have ACS880 family of drives only and you have no DDCS communication hardware in your PC, you may get tired about the message complaining about it each time you connect to DriveDA. There are two ways to get rid of this message. If you occasionally need to connect to an ACS800 family of drive, we recommend that you add or edit [OPC] section in the file dwc_def.ini: [OPC] Remote=1 The file is located in: ? Documents and Settings\All Users\Application Data\DriveWare (WinXP), or ? Program Data\DriveWare