MVME3604-6342機器人備件
右鍵單擊對話框中的“固定IP”列表將顯示上下文菜單?;蛘哒堊⒁猓部梢酝ㄟ^點擊Del鍵來刪除所選的固定IP。還請注意,如果“固定IP”列表中沒有條目或未選擇條目,則菜單中除“新建”以外的所有其他命令都將灰顯。8.1.9通過查找設備添加和刪除固定IP請注意,查找操作僅在UDP端口24576空閑且未被防火墻阻止時有效。要查找靠近或intranet設備的SAP/http設備的IP地址,請單擊配置設置對話框的查找組中的靠近設備或intranet設備按鈕。將顯示OPC服務器7-54 DriveWindow 2找到的設備對話框。在左側,您可以看到所選當前配置中未包含的SAP/http設備列表。在右側,您可以看到所選當前配置中包含的SAP/http設備列表。請注意,所選當前配置中未找到的SAP/http設備不會顯示在兩個列表中。所以你只能在這里操縱找到的設備。OPC服務器驅動窗口2 7-55現在您可以:?通過單擊>>按鈕添加所有找到的尚未包含的設備?通過單擊按鈕刪除所有找到的當前包含的設備。?通過在“包含”列表中單擊(按住Ctrl鍵或Shift鍵)并單擊>按鈕來選擇當前包含的選定設備,從而刪除這些設備。例如:OPC服務器7-56 DriveWindow 2最后單擊“確定”返回配置設置對話框。OPC服務器驅動窗口2 7-57現在可以在固定IP列表中看到更改。請注意,如果添加了新的NETA-21,則其RS-485總線都包含在內,并且固定IP列表中未顯示通道。當DriveDA連接時,DriveDA會自動連接到兩條總線,即保留兩個通道。8.1.10典型工作流程當您來到一個以太網段中有SAP/http設備的站點時,您的工作流程可能如這里所述。注意,在連接到DriveDA OPC服務器之前,不必啟用NETA-21面板網關。第一件事是打開SAP/http設備,等待3-5分鐘,使其啟動并運行。然后啟動DriveWindow,但不要連接到OPC服務器。從網絡菜單的配置子菜單中選擇SAP/http。OPC服務器7-58 DriveWindow 2從SAP/http配置對話框的編輯菜單中選擇新建。輸入可以輕松與站點關聯的新配置的名稱,然后單擊“確定”。OPC服務器驅動窗口2 7-59在“新配置的設置”對話框中啟用SAP/http通信。使此配置中的所有或許多SAP/http設備共用其他設置更改。
of the dialog box for Settings of a configuration and in the context menu, which is displayed if you right click the Fixed IPs listing in the dialog box. or Note that you can delete the selected Fixed IP also by hitting the Del key. Note also that if there is no entry in the Fixed IPs list or no entry is selected, all other commands than New are grayed in the menu. 8.1.9 Adding and Deleting Fixed IPs by Finding Devices Note that the Find operation works only if the UDP port 24576 is free and not blocked by the firewall. To find IP addresses of SAP/http devices near or intranet devices, click the Near Devices or Intranet Devices button in the Find group of the dialog box for Settings of a configuration. OPC Server 7-54 DriveWindow 2 The Devices Found dialog box is displayed. On the left side you have a list of SAP/http devices found that are not included in the selected Current configuration. On the right side you have a list of SAP/http devices found that are included in the selected Current configuration. Note that a SAP/http device included in the selected Current configuration that is not found is not displayed in either of the lists. So you can manipulate here only the devices found. OPC Server DriveWindow 2 7-55 Now you can: ? Add all found devices not yet included by clicking the >> button ? Delete all found devices currently included by clicking the button. ? Delete selected devices currently included by selecting them by clicking (with Ctrl or Shift key down) in the Include list and then clicking the > button. For example: OPC Server 7-56 DriveWindow 2 Finally click OK to get back to the dialog box for Settings of a configuration. OPC Server DriveWindow 2 7-57 The changes can now be seen in the Fixed IPs list. Note that if a new NETA-21 is added, both of its RS-485 buses are included and the channels are not shown in the Fixed IPs list. When DriveDA connection is made, DriveDA connects automatically to both buses, i.e., two channels are reserved. 8.1.10 Typical Workflow When you come to a site having SAP/http devices in an Ethernet segment, your workflow may be as explained here. Note that until you connect to the DriveDA OPC server, it is not necessary to have the panel gateway of NETA-21 enabled. The first thing is to put the SAP/http devices on and wait 3-5 minutes to get them up and running. Then start DriveWindow, but do not connect to an OPC Server. Select SAP/http from Configure submenu of the Network menu. OPC Server 7-58 DriveWindow 2 Select New from the Edit menu in the SAP/http Configuration dialog box. Enter a name for the new configuration that you can easily associate with the site and click OK. OPC Server DriveWindow 2 7-59 In the Settings for the new configuration dialog box enable SAP/http Communication. Make other setting changes common for all or many of the SAP/http devices in this configuration.







